A banquet hall hosts speeches at noon and a DJ at night. Most of those uses want the same thing: the boom under control so the stage is clear and guests can still talk at the tables.
Aim for a reverberation time of 0.72–1.08 s in the furnished room with its usual occupancy (centre: 0.90 s). Where music matters most, the target rises to about 1.2 s. Shorter isn't better: below the band the room sounds dead and people raise their voices.
Marble floor, plastered walls with mirrors and décor, a gypsum false ceiling with chandeliers, round tables and a stage on a short wall.
Lower NRC, a little more area: often the same result. The lowest NRC that reaches the target here is about 0.36.
Typical absorption values, Eyring's formula, speech frequencies. An estimate for early design. Run your own room in the tool.
Walls above 2.1 m (7 ft), clear of décor, plus the rear wall from 0.9 m. Ceiling: main zone, clear of chandeliers. The stage or head table is on the top wall of the plan.
Around 0.9 to 1.2 s when occupied. One target near 1 s covers weddings, speeches, dining and DJ nights reasonably well.
Each guest absorbs some sound. With half the guests, the hall loses a big share of its absorption, so the treatment should cover that gap.
Not much. Neighbour noise is about the walls, roof, doors and openings. Absorption inside lowers the level by only a few dB.
How long does the room ring now, and what should it be?
How much area, and how many panels, hit the target.
Rate a wall with its door, glass and gaps, and find the weak link.
Targets, worked examples and placement for eight room types.
Other rooms: Meeting rooms · Classrooms · Restaurants · Home theatres · Studios · Auditoriums · Worship halls
Occasional updates for architects and designers: new guides, tool features and what we learn on projects. No spam.
Built by Attuna, your acoustic guide. Attuna is the acoustics arm of Strawcture.
Indicative tools for early design, not a substitute for a formal acoustic assessment.