RT60 calculator

How long does the room ring now, what should it be for its use, and how much absorption closes the gap? Enter the room and its finishes; the answer updates as you type.

Room type
Length (m)
Width (m)
Height (m)
Floor
Walls
Ceiling
Furnishing
People in the room (usual)
NRC of the material
RT60 without treatment
1.14 s
Too live
Target for this room
0.55 s
band 0.44–0.66 s
just right · 0.44–0.66 s
too dead
too live
0 s0.51.01.5
on target
0.55 s
untreated
1.14 s
Area needed at NRC 0.7
19 m²

Spread over the walls and ceiling zones that suit a meeting / conference room, this brings it to 0.55 s.

What if: NRC 0.5 → 28 m², NRC 0.7 → 19 m², NRC 0.9 → 15 m².

See where it goes

The full tool adds placement drawings for every wall and the ceiling, a check on the wall next door, and sends the spec to your inbox.

Open the full tool

Eyring's formula with typical absorption values, at speech frequencies. Indicative, for early design.

How the RT60 is worked out

RT60 is the time a sound takes to fade by 60 dB once it stops. It depends on two things: the room's volume (V), and how much of the sound its surfaces, furniture and people absorb (A).

SabineRT60 = 0.161 · V / A
EyringRT60 = 0.161 · V / (−S · ln(1 − ᾱ) + Aobjects)

V in m³, S = total surface area in m², ᾱ = average absorption of the surfaces. Each surface contributes its area × its absorption coefficient; each seated person adds about 0.45 m².

The two formulas agree in lively rooms. Once a room is treated, Sabine overstates the reverberation, and so overstates how much material you need. This calculator uses Eyring. Both assume the absorption is spread around the room; with everything on the ceiling, real rooms often ring longer than either predicts.

Typical RT60 targets

Meeting / conference room0.55 s
Home theatre0.35 s
Classroom / training0.55 s
Restaurant / social0.7 s
Studio0.35 s
Banquet hall0.9 s speech · 1.2 s music
Auditorium1 s speech · 1.6 s music
Worship hall1 s speech · 1.8 s music

Mid-frequency targets for an occupied, furnished room. A band of ±20% around each works.

Common questions

Is a lower RT60 always better?

No. Below the band the room goes dead: speech loses energy, people raise their voices, and music sounds flat. Aim for the band, not the minimum. See why higher NRC isn't automatically better.

Why doesn't the estimate match a measurement?

The calculator uses typical absorption values for finishes, furniture and people, at speech frequencies. Real finishes vary, and bass behaves differently. If the room exists, measure it: the full tool has a phone estimate built in, and an on-site measurement gives the real figures.

Does RT60 change with people in the room?

Yes, noticeably. Each seated person adds roughly 0.45 m² of absorption, so a full meeting room or hall rings less than an empty one. The calculator lets you set the usual occupancy.

What's the difference between RT60 and NRC?

RT60 describes the room. NRC describes a material: the average of its absorption at 250, 500, 1000 and 2000 Hz. You choose a material's NRC and area to hit the room's RT60 target. More on NRC.

Keep up with acoustics

Occasional updates for architects and designers: new guides, tool features and what we learn on projects. No spam.

Attuna

Built by Attuna, your acoustic guide. Attuna is the acoustics arm of Strawcture.

Indicative tools for early design, not a substitute for a formal acoustic assessment.