In a classroom, the students at the back should hear the teacher as clearly as the front row. A long reverberation time blurs consonants, and younger children and second-language learners lose the most.
Aim for a reverberation time of 0.44–0.66 s in the furnished room with its usual occupancy (centre: 0.55 s). Shorter isn't better: below the band the room sounds dead and people raise their voices.
Kota stone or tile floor, plastered brick walls, a bare RCC slab with ceiling fans, windows along one side and a door at the back.
Lower NRC, a little more area: often the same result. The lowest NRC that reaches the target here is about 0.46.
Typical absorption values, Eyring's formula, speech frequencies. An estimate for early design. Run your own room in the tool.
Rear wall from 0.9 m up; the board wall stays bare. Ceiling: most of it, with a bare strip over the teacher. The board is on the top wall of the plan.
About 0.4 to 0.6 s for a typical classroom. The US classroom standard, ANSI/ASA S12.60, sets a maximum of 0.6 s for core learning spaces up to 283 m³.
Fans add background noise, and their hooks limit where ceiling panels can go. Leave clearance around each fan and fill the rest of the ceiling first.
Yes. Panels can be fixed directly to the slab between fans, or hung as rafts, and the rear wall can be treated from 0.9 m up.
How long does the room ring now, and what should it be?
How much area, and how many panels, hit the target.
Rate a wall with its door, glass and gaps, and find the weak link.
Targets, worked examples and placement for eight room types.
Other rooms: Meeting rooms · Restaurants · Home theatres · Studios · Banquet halls · Auditoriums · Worship halls
Occasional updates for architects and designers: new guides, tool features and what we learn on projects. No spam.
Built by Attuna, your acoustic guide. Attuna is the acoustics arm of Strawcture.
Indicative tools for early design, not a substitute for a formal acoustic assessment.